Tremont & Gulf 4-6-0 "Ten-wheeler" Locomotives of the USA


Class Details by Steve Llanso of Sweat House Media

Class 19 (Locobase 12892)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 30, p. 227. Works numbers were 30777, 30866 in May 1907.

The 20 was eventually sold to the Tavares & Gulf, the Tropical Trunk Line (or "Tug and Grunt") based in Florida.


Class 25 (Locobase 12895)

Data from Baldwin Locomotive Works Specification for Engines as digitized by the DeGolyer Library of Southern Methodist University Volume 48, p. 259. Works number was 40318 in August 1913.

Like most of the bought-new T & G locomotives, this Ten-wheeler stayed with the short line for decades. Only in 1953 was it sold to Dunham-Stephens

Specifications by Steve Llanso of Sweat House Media
Class1925
Locobase ID12,892 12,895
RailroadTremont & GulfTremont & Gulf
CountryUSAUSA
Whyte4-6-04-6-0
Number in Class21
Road Numbers19-2025
GaugeStdStd
Number Built21
BuilderBurnham, Williams & CoBaldwin
Year19071913
Valve GearStephensonStephenson
Locomotive Length and Weight
Driver Wheelbase (ft)11.3312
Engine Wheelbase (ft)21.5823.12
Ratio of driving wheelbase to overall engine wheebase 0.53 0.52
Overall Wheelbase (engine & tender) (ft)54.25
Axle Loading (Maximum Weight per Axle) (lbs)
Weight on Drivers (lbs)95,000107,800
Engine Weight (lbs)121,000134,000
Tender Loaded Weight (lbs)80,000110,000
Total Engine and Tender Weight (lbs)201,000244,000
Tender Water Capacity (gals)40005500
Tender Fuel Capacity (oil/coal) (gals/tons)10
Minimum weight of rail (calculated) (lb/yd)5360
Geometry Relating to Tractive Effort
Driver Diameter (in)5654
Boiler Pressure (psi)180180
High Pressure Cylinders (dia x stroke) (in)18" x 24"19" x 26"
Tractive Effort (lbs)21,24526,594
Factor of Adhesion (Weight on Drivers/Tractive Effort) 4.47 4.05
Heating Ability
Firebox Area (sq ft)146152
Grate Area (sq ft)22.4024.30
Evaporative Heating Surface (sq ft)16281920
Superheating Surface (sq ft)
Combined Heating Surface (sq ft)16281920
Evaporative Heating Surface/Cylinder Volume230.31225.03
Computations Relating to Power Output (More Information)
Robert LeMassena's Power Computation40324374
Same as above plus superheater percentage40324374
Same as above but substitute firebox area for grate area26,28027,360
Power L156045089
Power MT390.15312.23